Electrolyte Analyser
Electrolyte Analyser
Features:
●The software supports automatic potential tracking correction to ensure stable performance
●Automatic monitoring and filtering of tiny air bubbles to ensure measurement accuracy
●Wave flushing and pipeline flushing can avoid blockage and cross-contamination
●Power-off protection, can protect data storage, the result can be stored up to 50,000
●Low consumption, effectively reducing the cost of consumables
●7-inch high-definition touch screen, comprehensive content display
●With the function of automatic fault alarm and elimination, improve work efficiency
Parameters:
Model |
BKE-A/B/C/D |
BKE-E/F/L |
Sample |
Serum, plasma,, cerebrospinal fluid and dilute urine |
|
Measuring Speed |
≤25s |
|
Analysis Method |
Ion selective electrode (ISE) |
|
Sample Volume |
60~150μl |
200μl |
Sample Position |
30 sample positions, 5 emergency positions,(Only for BKE-B/D/F/L) |
|
Injection mode |
Manual or automatic injection can be selected(Only for BKE-B/D/F/L), BKE-A/C/E is manually injection |
|
Storage |
Up to 50,000 test results |
|
Printer |
Build-in thermal printer |
|
Interface |
RS232 port for LIS |
|
Display |
7-inch high-definition touch screen |
|
Language |
Chinese and English, other languages can be customized |
|
Calibration |
Automatic and Manual calibration |
|
Other Function |
Sample volume detection |
|
Power Supply |
AC110~240V,50/60Hz, 70VA |
|
Temperature |
+10~+40℃ |
|
Relative Humidity |
≤ 80 % |
|
Atmospheric Pressure |
86~106 kPa |
Model |
BKE-A |
BKE-B |
BKE-C |
Test Items |
K+, Na+, Cl- |
K+, Na+, Cl- |
K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH |
Sample Tray |
No |
Yes |
No |
External Size(W*D*H) |
405*214*471mm |
6628*287*471mm |
405*214*471mm |
Net Weight |
12.48 |
15.11 |
12.48 |
Package Size(W*D*H) |
Instrument:500*390*530mm Reagent:220*160*120, 220*160*120 |
Instrument:390*500*720 mm Reagent:220*160*120, 220*160*120 |
Instrument:390*500*530 mm Reagent:220*160*120, 220*160*120 |
Gross Weight |
Instrument:16.08 Reagent:1.7, 0.9 |
Instrument:19.31 Reagent:1.7, 0.9 |
Instrument:16.08 Reagent:1.7, 0.9 |
Model |
BKE-D |
BKE-E |
BKE-F |
Test Items |
K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH |
K+, Na+, Cl-, iCa2+, nCa2+,TCa2+, pH, TCO2, AG |
K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG |
Sample Tray |
Yes |
No |
Yes |
External Size(W*D*H) |
682*287*471 |
405*214*471 |
682*287*471 |
Net Weight |
11.9kg |
13.13 |
15.76 |
Package Size(W*D*H) |
Instrument:500*390*720 Reagent:220*160*120, |
Instrument:500*390*530 Reagent:280*135*210, |
Instrument:500*390*720 Reagent:280*135*210, |
Gross Weight |
Instrument:19.31 Reagent:1.7, 0.9 |
Instrument:16.73 Reagent:2.2, 1.2 |
Instrument:19.96 Reagent:2.2, 1.2 |
Model |
BKE-L |
||
Test Items |
K+, Na+, Cl-, iCa2+, nCa2+, TCa2+, pH, TCO2, AG, Li+, Mg2+ |
||
Sample Tray |
Yes |
||
External Size(W*D*H) |
682*287*471 |
||
Net Weight |
15.76 |
||
Package Size(W*D*H) |
Instrument:500*390*720 Reagent:280*135*210, |
||
Gross Weight |
Instrument:19.96 Reagent:2.2, 1.2 |
Items |
Measuring Range |
Resolution |
K+ |
0.5-20.0mmol/L |
0.01 mmol/L |
Na+ |
15-200mmol/L |
0.01 mmol/L |
Cl- |
15-200mmol/L |
0.01 mmol/L |
Ca2+ |
0.1-6.0mmol/L |
0.01 mmol/L |
pH |
4-9pH |
0.01 pH |
TCO2 |
2.0-70.0mmol/L |
0.1 mmol/L |
Li+ |
0.1-6.0mmol/L |
0.01 mmol/L |
Mg2+ |
0.1-4.0mmol/L |
0.01 mmol/L |